AT2327 Alarm Dosimeter with Data Display

Alarm dosimeter is intended for radiation monitoring of radiation-sensitive and radiation-dangerous areas and facilities.


Operating principle

Gamma smart probe is used for measuring of radiation background level.
Dosimeter operation algorithm provides measurement continuity, rapid reaction to background radiation level change and real time display of detection unit data on external display.
Ambient temperature and current time and date is additionally displayed.
Control unit is responsible for controlling the operation modes, performing necessary calculations, storing and backing-up measurement results, as well as for supplying power to devices. It hosts command console, interface adapter and backup power supply.
Control unit is to be installed indoors.

 

 

Application

  • Coach and railway terminals, airports, underground railway systems
  • Civil defence and security services facilities, high-security objects
  • Manufacturing facilities
  • Radiation detection and dosimetric laboratories
  • Radiological health care facilities
  • Nuclear industry facilities

 
Features

  • Wide range of gamma radiation dose rate measurement from background to emergency values
  • Smart probe for gamma radiation measuring
  • Automatic compensation of intrinsic detector background
  • Can be operated over a wide temperature range
  • High reliability
  • Operational self check and fault diagnostics
  • Integrated backup power supply for up to 3 hour of off-line operation
  • History logging of dose rate levels and cases of threshold crossing
  • Detection unit can be installed up to 1 km away from data display
  • Additional protection from direct weather impact
  • No dismantling for servicing


AT2327 Alarm Dosimeter meets
International standard requirements: IEC 61017-1:1991,  EN 50371:2002
Safety standard requirements: IEC 61010-1:1990
EMC requirements: EN 55022:1998+A1:2000+A2:2003, EN 55024:1998+A1:2001+A2:2003
IEC 61000-4-2:2006,  IEC 61000-4-3:2008,  IEC 61000-4-4:2004,  IEC 61000-4-5:2005
IEC 61000-4-11:2004
 
Alarm Dosimeter has the pattern approval certificates of Republic of Belarus, Russian Federation, Ukraine and Kazakhstan.

Features

Dose rate
Ambient temperature
Current date and time
Registered radiation type Gamma radiation
Detector Geiger-Muller counter tube
Measurement range of ambient radiation 0.1 µSv/h – 10 Sv/h (10 µR/h – 1000 R/h)
dose rate equivalent  
Basic fractional error of dose rate ±15% max.
measurement  
Energy range 60 keV - 3 MeV
Sensitivity 4.0 cps/µSv·h-1
Energy dependence of sensibility within -25% to +35%
energy ranges of 60 keV to 1.25 MeV  
Ambient temperature monitoring range -30°C to +50°C
Data display LED display with step brightness control
     Displayed information Dose rate, ambient temperature,
  current time and date
     Time format Hours:Minutes, Days:Months
     Maximum legibility distance at any time 30 m
     of day  
Working temperature range  
     Detection unit and data display -30°C to +50°C
     Control unit +5°C to +40°C
Relative humidity with air temperature +35°C Up to 95%
without condensation  
Protection class  
     Detection unit IP57
     Data display IP21
     Control unit IP50
Power supply 230 V(± 23 V), 50±1 Hz
Backup power supply Integrated backup power supply 12 V
  and +24 V
Power consumption Up to 100 W
Overall dimensions  
     Data display with detection unit 1095x392x300 mm
     Control unit 500x650x150 mm
Weight  
     Data display with detection unit 25 kg
     Control unit 30 kg

Design and specifications are subject to change without notice

AttachmentSize
Download brochure420.22 KB